CompuLan Center dba/Digital IDView Technologies
12000 Ford Road, Suite 110, Dallas TX 75234
83
Possible reasons are as followed:
1 When using the BNC output, the option between the N mode and PAL mode is wrong and
the image becomes black and white.
2 The DVR does not matched the monitor impedance.
3 The video transmission distance is too far or the loss of the video transmission line is too
large.
4 The color and brightness setting of the DVR is wrong.
6、 I can not find the video files in local playback mode.
Possible reasons are as followed:
1 The data line of the hard disk is damaged.
2 The hard disk is damaged.
3 Update the different program with the origin program files.
4 The video files to look up are covered.
5 The recording is not on.
7、 The local video is not clear.
Possible reasons are as followed:
1 The image quality is too bad.
2 The reading program is wrong. Reboot up the DVR.
3 The data line of the hard disk is damaged.
4 The hard disk is damaged.
5 The hardware of the DVR is damaged.
8、 There is no audio signal in the surveillance window.
Possible reasons are as followed:
1 It is not an active tone arm.
2 It is not an active sound box.
3 The audio lines are damaged.
4 The hardware of the DVR is damaged.
9、 There is audio signal in the surveillance window but no audio signal in the playback state.
Possible reasons are as followed:
1 Setting issues: the audio option is not chosen.
2 The according channel is not connected with the video.
10、 The time is wrong.
Possible reasons are as followed:
1 Setting is wrong...
2 The battery is in bad connection or the voltage is too low.
3 The oscillation is damaged.
11、 The DVR can not control the PTZ.
Possible reasons are as followed: